Tags
analysis cell culture cell labeling chromatin cloning coding communication confocal data analysis embryo collection embryo labeling figures fly work genomics hb image analysis image processing images in situs Library2 literature making antibodies matlab-storm meetings modeling MP12 mRNA counting Ph planning presentation probe making project 2 project2 result results sectioning section staining shadow enhancers sna snail staining STORM STORM analysis troubleshooting writing-
GitHub Projects
Tag Archives: troubleshooting
Thursday 12/12/13
10:45a – 11:00p Ph Simulations Troubleshooting extra along bonds. Oops, actually just resulted from plotting the wrong attachment matrix for the given position list. Simulations ran at subsaturating Ph — more total sites than available Ph. Hence there is a … Continue reading
Posted in Summaries
Tagged cell labeling, coding, Ph, troubleshooting
Comments Off on Thursday 12/12/13
denaturing diagnostic gels
Gel 1, 5% Agarose, 200 V in sodium-Borax (300 V melts gel). Gel 2, 15% Urea, 120V 2 hrs Gel 3 15% Urea gel, 120 V 50 min in 37C room Gel 4, 10% precast Urea denaturing gel, 120 V, … Continue reading
Posted in probe and plasmid building
Tagged images, troubleshooting
Comments Off on denaturing diagnostic gels
Thursday 04/11/13
Oligo Paint Probe synthesis Test PCRs at 1 mL scale: Assymetric y-PCR, Y-adapter, no Y-L primer + 1uL of EtOH extracted Y PCR product at 85 ng/uL Assymetric b-PCR, B-adapter + 1 uL of EtOH extracted B PCR product at … Continue reading
Protected: Activator oligoPaints: results summary 04/05/13
There is no excerpt because this is a protected post.
Posted in Chromatin
Tagged results, troubleshooting
Comments Off on Protected: Activator oligoPaints: results summary 04/05/13
Protected: issues with ph-FLAG round 1
There is no excerpt because this is a protected post.
Posted in Chromatin
Tagged images, STORM, troubleshooting
Comments Off on Protected: issues with ph-FLAG round 1
oligopaint-PCR
Calculating concentrations (Qubit) and molecule numbers: starting primer = 30 ng in 300 uL in 1 ng/uL, added 100 uL = 100 ng 100 uM = 100E-12 mols/uL add 100 uL, = 10 nmols starting primer. Y PCR: 73.7 ng/mL … Continue reading
Tuesday 03/05/13
9:50 A – 7:30 P, 8:30 P – 10:50 P General Discussing replies for Banff invites. Student substitutions add to bottom of list Still need to write more acknowledgement of replies. STORM Analysis launch analysis of all unprocessed datafiles. ESATA … Continue reading
Posted in Summaries
Tagged coding, images, open problem, section staining, troubleshooting
Comments Off on Tuesday 03/05/13
embryo sections
some sections lie nice and flat, others get substantial ripples. Is this knife compression? too large a section in x-y? (seems to correlate). Too thick a section? (seems also to be true in my experience).
Z-calibration part 2
Curves fit the following polynomial: $latex w_x=\sqrt{w_{x0} \sqrt{B_xX^4+A_xX^3+X^2+1}}$ where $latex X= (z-g_x)/(z_{rx})$ In general we will require $latex gx$ to be negative $latex gy$ to be positive. $latex Ax$ and $latex Bx$ are correction factors and should be small. See … Continue reading
Posted in General STORM
Tagged coding, troubleshooting, z-calibration
Comments Off on Z-calibration part 2
issues with non-blinking weak spots
The very bright, round foci clearly do not correspond to objects in the conventional image and are probably all artificats from non-switching foci. These dots start off at moderate single molecule brightness (can’t eliminate them just using higher threshold cutoff … Continue reading
Posted in General STORM
Tagged images, troubleshooting
Comments Off on issues with non-blinking weak spots