10:45a – 11:00p Ph Simulations Troubleshooting extra along bonds. Oops, actually just resulted from plotting the wrong attachment matrix for the given position list. Simulations ran at subsaturating Ph — more total sites than available Ph. Hence there is a … Continue reading

Posted in Summaries | Tagged , , , | Comments Off on Thursday 12/12/13

denaturing diagnostic gels

Gel 1, 5% Agarose, 200 V in sodium-Borax (300 V melts gel). Gel 2, 15% Urea, 120V 2 hrs Gel 3 15% Urea gel, 120 V 50 min in 37C room Gel 4, 10% precast Urea denaturing gel, 120 V, … Continue reading

Posted in probe and plasmid building | Tagged , | Comments Off on denaturing diagnostic gels

Thursday 04/11/13

Oligo Paint Probe synthesis Test PCRs at 1 mL scale: Assymetric y-PCR, Y-adapter, no Y-L primer + 1uL of EtOH extracted Y PCR product at 85 ng/uL Assymetric b-PCR, B-adapter + 1 uL of EtOH extracted B PCR product at … Continue reading

Posted in Summaries | Tagged , | Comments Off on Thursday 04/11/13

Protected: Activator oligoPaints: results summary 04/05/13

There is no excerpt because this is a protected post.

Posted in Chromatin | Tagged , | Comments Off on Protected: Activator oligoPaints: results summary 04/05/13

Protected: issues with ph-FLAG round 1

There is no excerpt because this is a protected post.

Posted in Chromatin | Tagged , , | Comments Off on Protected: issues with ph-FLAG round 1

oligopaint-PCR

Calculating concentrations (Qubit) and molecule numbers: starting primer = 30 ng in 300 uL in 1 ng/uL, added 100 uL = 100 ng 100 uM = 100E-12 mols/uL add 100 uL, = 10 nmols starting primer. Y PCR: 73.7 ng/mL … Continue reading

Posted in probe and plasmid building | Tagged , | Comments Off on oligopaint-PCR

Tuesday 03/05/13

9:50 A – 7:30 P, 8:30 P – 10:50 P General Discussing replies for Banff invites. Student substitutions add to bottom of list Still need to write more acknowledgement of replies. STORM Analysis launch analysis of all unprocessed datafiles. ESATA … Continue reading

Posted in Summaries | Tagged , , , , | Comments Off on Tuesday 03/05/13

embryo sections

some sections lie nice and flat, others get substantial ripples. Is this knife compression? too large a section in x-y? (seems to correlate). Too thick a section? (seems also to be true in my experience).

Posted in Chromatin, Microscopy | Tagged , | Comments Off on embryo sections

Z-calibration part 2

Curves fit the following polynomial: $latex w_x=\sqrt{w_{x0} \sqrt{B_xX^4+A_xX^3+X^2+1}}$ where $latex X= (z-g_x)/(z_{rx})$ In general we will require $latex gx$ to be negative $latex gy$ to be positive. $latex Ax$ and $latex Bx$ are correction factors and should be small. See … Continue reading

Posted in General STORM | Tagged , , | Comments Off on Z-calibration part 2

issues with non-blinking weak spots

The very bright, round foci clearly do not correspond to objects in the conventional image and are probably all artificats from non-switching foci. These dots start off at moderate single molecule brightness (can’t eliminate them just using higher threshold cutoff … Continue reading

Posted in General STORM | Tagged , | Comments Off on issues with non-blinking weak spots